More results...

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Abdominal Radiology, Original Research
Abdominal Radiology, Pictorial Essay
Anthropology and Dental Radiology, Original Research
Breast Imaging, Case Report
Breast Imaging, Original Research
Breast Imaging, Pictorial Essay
Breast Imaging, Review Article
Cardiopulmonary Imaging, Case Report
Cardiopulmonary Imaging, Case Series
Cardiopulmonary Imaging, Education
Cardiopulmonary Imaging, Original Research
Cardiopulmonary Imaging, Pictorial Essay
Cardiopulmonary Imaging, Review Article
Case Report
Case Report, Breast Imaging
Case Report, Cardiopulmonary Imaging
Case Report, Diagnostic Radiology
Case Report, Neuroradiology/Head and Neck Imaging
Case Report, Vascular and Interventional Radiology
Case Series
Case Series, Diagnostic Radiology
Case Series, Vascular and Interventional Radiology
DENTAL ARTICLE
Dental Radiology, Case Report
Dental Radiology, Case Series
Dental Radiology, Original Research
Diagnostic Radiology, Case Report
Diagnostic Radiology, Case Series
Diagnostic Radiology, Original Research
Diagnostic Radiology, Pictorial Essay
Diagnostic Radiology, Review Article
Editorial
Education, Original Research
Emergency, Original Research
Erratum
Gastrointestinal Imaging, Case Report
Gastrointestinal Imaging, Case Series
Gastrointestinal Imaging, Original Research
Gastrointestinal Imaging, Pictorial Essay
General and Emergency Radiology, Original Research
General and Emergency Radiology, Review Article
Genitourinary and Gynecologic Imaging, Case Report
Genitourinary and Gynecologic Imaging, Original Research
Imaging Science, Original Research
Interventional Radiology, Original Research
Letter to Editor
Musculoskeletal Imaging, Case Report
Musculoskeletal Imaging, Original Article
Musculoskeletal Imaging, Original Research
Musculoskeletal Imaging, Pictorial Essay
Musculoskeletal Imaging, Review Article
Neuroradiology , Review Article
Neuroradiology Head and Neck Imaging, Pictorial Essay
Neuroradiology, Case Report
Neuroradiology, Pictorial Essay
Neuroradiology/Head and Neck Imaging, Case Report
Neuroradiology/Head and Neck Imaging, Case Series
Neuroradiology/Head and Neck Imaging, Original Research
Neuroradiology/Head and Neck Imaging, Review Article
Neuroradiology/Spine Imaging, Original Research
Nuclear Medicine, Case Report
Nuclear Medicine, Original Research
Nuclear Medicine, Pictorial Essay
Original Article
Original Article, Neuroradiology
Original Research
Original Research Article
Original Research, Dental Radiology
Original Research, Descriptive Study
Original Research, Diagnostic Radiology
Original Research, Gastrointestinal Imaging
Original Research, Genitourinary and Gynecologic Imaging
Original Research, Musculoskeletal Imaging
Original Research, Neuroradiology/Head and Neck Imaging
Original Research, Nuclear Medicine
Original Research, Vascular and Interventional Radiology
Pediatric Imaging, Case Report
Pediatric Imaging, Pictorial Essay
PICTORIAL ESSAY
PICTORIAL REVIEW
Radiologic-Pathologic Correlation
RADIOLOGICAL-PATHOLOGICAL CORRELATION
Radiology Business, Original Research
Research Article
Review Article
Review Article, Diagnostic Radiology
Review Article, Gastrointestinal imaging
Review Article, Musculoskeletal
Review Article, Vascular and Interventional Radiology
Technical Innovation
Technical Innovation, Gastrointestinal Imaging
Ultrasound, Case Report
Ultrasound, Original Research
Ultrasound, Review Article
Vascular and International Radiology, Case Report
Vascular and Interventional Radiology, Case Report
Vascular and Interventional Radiology, Case Series
Vascular and Interventional Radiology, Original Research
Vascular and Interventional Radiology, Pictorial Essay
Vascular and Interventional Radiology, Review Article
Vascular and Interventional Radiology, Short Communication
Vascular and Interventional, Original Research

More results...

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Abdominal Radiology, Original Research
Abdominal Radiology, Pictorial Essay
Anthropology and Dental Radiology, Original Research
Breast Imaging, Case Report
Breast Imaging, Original Research
Breast Imaging, Pictorial Essay
Breast Imaging, Review Article
Cardiopulmonary Imaging, Case Report
Cardiopulmonary Imaging, Case Series
Cardiopulmonary Imaging, Education
Cardiopulmonary Imaging, Original Research
Cardiopulmonary Imaging, Pictorial Essay
Cardiopulmonary Imaging, Review Article
Case Report
Case Report, Breast Imaging
Case Report, Cardiopulmonary Imaging
Case Report, Diagnostic Radiology
Case Report, Neuroradiology/Head and Neck Imaging
Case Report, Vascular and Interventional Radiology
Case Series
Case Series, Diagnostic Radiology
Case Series, Vascular and Interventional Radiology
DENTAL ARTICLE
Dental Radiology, Case Report
Dental Radiology, Case Series
Dental Radiology, Original Research
Diagnostic Radiology, Case Report
Diagnostic Radiology, Case Series
Diagnostic Radiology, Original Research
Diagnostic Radiology, Pictorial Essay
Diagnostic Radiology, Review Article
Editorial
Education, Original Research
Emergency, Original Research
Erratum
Gastrointestinal Imaging, Case Report
Gastrointestinal Imaging, Case Series
Gastrointestinal Imaging, Original Research
Gastrointestinal Imaging, Pictorial Essay
General and Emergency Radiology, Original Research
General and Emergency Radiology, Review Article
Genitourinary and Gynecologic Imaging, Case Report
Genitourinary and Gynecologic Imaging, Original Research
Imaging Science, Original Research
Interventional Radiology, Original Research
Letter to Editor
Musculoskeletal Imaging, Case Report
Musculoskeletal Imaging, Original Article
Musculoskeletal Imaging, Original Research
Musculoskeletal Imaging, Pictorial Essay
Musculoskeletal Imaging, Review Article
Neuroradiology , Review Article
Neuroradiology Head and Neck Imaging, Pictorial Essay
Neuroradiology, Case Report
Neuroradiology, Pictorial Essay
Neuroradiology/Head and Neck Imaging, Case Report
Neuroradiology/Head and Neck Imaging, Case Series
Neuroradiology/Head and Neck Imaging, Original Research
Neuroradiology/Head and Neck Imaging, Review Article
Neuroradiology/Spine Imaging, Original Research
Nuclear Medicine, Case Report
Nuclear Medicine, Original Research
Nuclear Medicine, Pictorial Essay
Original Article
Original Article, Neuroradiology
Original Research
Original Research Article
Original Research, Dental Radiology
Original Research, Descriptive Study
Original Research, Diagnostic Radiology
Original Research, Gastrointestinal Imaging
Original Research, Genitourinary and Gynecologic Imaging
Original Research, Musculoskeletal Imaging
Original Research, Neuroradiology/Head and Neck Imaging
Original Research, Nuclear Medicine
Original Research, Vascular and Interventional Radiology
Pediatric Imaging, Case Report
Pediatric Imaging, Pictorial Essay
PICTORIAL ESSAY
PICTORIAL REVIEW
Radiologic-Pathologic Correlation
RADIOLOGICAL-PATHOLOGICAL CORRELATION
Radiology Business, Original Research
Research Article
Review Article
Review Article, Diagnostic Radiology
Review Article, Gastrointestinal imaging
Review Article, Musculoskeletal
Review Article, Vascular and Interventional Radiology
Technical Innovation
Technical Innovation, Gastrointestinal Imaging
Ultrasound, Case Report
Ultrasound, Original Research
Ultrasound, Review Article
Vascular and International Radiology, Case Report
Vascular and Interventional Radiology, Case Report
Vascular and Interventional Radiology, Case Series
Vascular and Interventional Radiology, Original Research
Vascular and Interventional Radiology, Pictorial Essay
Vascular and Interventional Radiology, Review Article
Vascular and Interventional Radiology, Short Communication
Vascular and Interventional, Original Research

More results...

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Abdominal Radiology, Original Research
Abdominal Radiology, Pictorial Essay
Anthropology and Dental Radiology, Original Research
Breast Imaging, Case Report
Breast Imaging, Original Research
Breast Imaging, Pictorial Essay
Breast Imaging, Review Article
Cardiopulmonary Imaging, Case Report
Cardiopulmonary Imaging, Case Series
Cardiopulmonary Imaging, Education
Cardiopulmonary Imaging, Original Research
Cardiopulmonary Imaging, Pictorial Essay
Cardiopulmonary Imaging, Review Article
Case Report
Case Report, Breast Imaging
Case Report, Cardiopulmonary Imaging
Case Report, Diagnostic Radiology
Case Report, Neuroradiology/Head and Neck Imaging
Case Report, Vascular and Interventional Radiology
Case Series
Case Series, Diagnostic Radiology
Case Series, Vascular and Interventional Radiology
DENTAL ARTICLE
Dental Radiology, Case Report
Dental Radiology, Case Series
Dental Radiology, Original Research
Diagnostic Radiology, Case Report
Diagnostic Radiology, Case Series
Diagnostic Radiology, Original Research
Diagnostic Radiology, Pictorial Essay
Diagnostic Radiology, Review Article
Editorial
Education, Original Research
Emergency, Original Research
Erratum
Gastrointestinal Imaging, Case Report
Gastrointestinal Imaging, Case Series
Gastrointestinal Imaging, Original Research
Gastrointestinal Imaging, Pictorial Essay
General and Emergency Radiology, Original Research
General and Emergency Radiology, Review Article
Genitourinary and Gynecologic Imaging, Case Report
Genitourinary and Gynecologic Imaging, Original Research
Imaging Science, Original Research
Interventional Radiology, Original Research
Letter to Editor
Musculoskeletal Imaging, Case Report
Musculoskeletal Imaging, Original Article
Musculoskeletal Imaging, Original Research
Musculoskeletal Imaging, Pictorial Essay
Musculoskeletal Imaging, Review Article
Neuroradiology , Review Article
Neuroradiology Head and Neck Imaging, Pictorial Essay
Neuroradiology, Case Report
Neuroradiology, Pictorial Essay
Neuroradiology/Head and Neck Imaging, Case Report
Neuroradiology/Head and Neck Imaging, Case Series
Neuroradiology/Head and Neck Imaging, Original Research
Neuroradiology/Head and Neck Imaging, Review Article
Neuroradiology/Spine Imaging, Original Research
Nuclear Medicine, Case Report
Nuclear Medicine, Original Research
Nuclear Medicine, Pictorial Essay
Original Article
Original Article, Neuroradiology
Original Research
Original Research Article
Original Research, Dental Radiology
Original Research, Descriptive Study
Original Research, Diagnostic Radiology
Original Research, Gastrointestinal Imaging
Original Research, Genitourinary and Gynecologic Imaging
Original Research, Musculoskeletal Imaging
Original Research, Neuroradiology/Head and Neck Imaging
Original Research, Nuclear Medicine
Original Research, Vascular and Interventional Radiology
Pediatric Imaging, Case Report
Pediatric Imaging, Pictorial Essay
PICTORIAL ESSAY
PICTORIAL REVIEW
Radiologic-Pathologic Correlation
RADIOLOGICAL-PATHOLOGICAL CORRELATION
Radiology Business, Original Research
Research Article
Review Article
Review Article, Diagnostic Radiology
Review Article, Gastrointestinal imaging
Review Article, Musculoskeletal
Review Article, Vascular and Interventional Radiology
Technical Innovation
Technical Innovation, Gastrointestinal Imaging
Ultrasound, Case Report
Ultrasound, Original Research
Ultrasound, Review Article
Vascular and International Radiology, Case Report
Vascular and Interventional Radiology, Case Report
Vascular and Interventional Radiology, Case Series
Vascular and Interventional Radiology, Original Research
Vascular and Interventional Radiology, Pictorial Essay
Vascular and Interventional Radiology, Review Article
Vascular and Interventional Radiology, Short Communication
Vascular and Interventional, Original Research
View/Download PDF

Translate this page into:

Gastrointestinal Imaging
Original Research
2021
:11;
50
doi:
10.25259/JCIS_72_2021

Decrease in Pancreatic Perfusion of Patients with Type 2 Diabetes Mellitus Detected by Perfusion Computed Tomography

Department of Radiology, Hospital de Clínicas de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil
Department of Radiology, Institute Jules Bordet, Brussels, Belgium
Department of Endocrinology, Hospital de Clínicas de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil
Corresponding author: Tiago Severo Garcia, Department of Radiology, Hospital de Clínicas de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil. tseverogarcia@hcpa.edu.br
Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Garcia TS, Engelholm JL, Vouche M, Leitão CB. Decrease in pancreatic perfusion of patients with type 2 diabetes mellitus detected by perfusion computed tomography. J Clin Imaging Sci 2021;11:50.

Abstract

Objectives:

The objectives of the study was to compare pancreatic perfusion by computed tomography in type 2 diabetes and non-diabetic subjects.

Material and Methods:

In this case–control study, 17 patients with type 2 diabetes and 22 non-diabetic controls were examined with a dynamic 192-slices perfusion computed tomography for estimating pancreatic perfusion parameters.

Results:

Thirty-nine patients were included (22 with Type 2 diabetes mellitus [T2DM]), with a mean age of 64 years. There were significant differences in some pancreatic perfusion parameters in patients with and without type 2 diabetes. Blood volume (BV) was lower in pancreatic head (with T2DM: 14.0 ± 3.4 vs. without T2DM: 16.1 ± 2.4 mL/100 mL; P = 0.033), pancreatic tail (with: 14.4 ± 3.6 vs. without: 16.8 ± 2.5 mL/100 mL; P = 0.023), and in whole pancreas (with: 14.2 ± 3.2 vs. without: 16.2 ± 2.5 mL/100 mL; P = 0.042). Similar behavior was observed with mean transit time (MTT) in pancreatic head (with: 7.0 ± 1.0 vs. without: 7.9 ± 1.2 s; P = 0.018), pancreatic tail (with: 6.6 ± 1.3 vs. without: 7.7 ± 0.9 s; P = 0.005), and in whole pancreas (with: 6.8 ± 1.0 vs. without: 7.7 ± 0.9 s; P = 0.016). BV in head, tail, and whole pancreas had negative correlations with age (head r: –0.352, P = 0.032; tail r: –0.421, P = 0.031; whole pancreas r: –0.439, P = 0.007), and fasting plasma glucose (head r: –0.360, P = 0.031; tail r: –0.483, P = 0.003; whole pancreas r: –0.447, P = 0.006). In a multivariate linear regression model, HbA1c was independently associated with decrease in BV in whole pancreas (β: –0.884; CI95%: –1.750 to –0.017; P = 0.046).

Conclusion:

Pancreatic BV and MTT were significantly lower in patients with type 2 diabetes. BV was decreased with older age and poorer glycemic control.

Keywords

Type 2 diabetes mellitus
Pancreas
Radiology
Tomography
Perfusion imaging

INTRODUCTION

Diabetes mellitus (DM) is characterized by chronic hyperglycemia resulting from increased peripheral insulin resistance and/or decreased insulin secretion.[1] Type 1 DM (T1DM) is caused by autoimmune destruction of pancreatic beta cells, while in type 2 DM (T2DM) the pathogenic mechanism is related to an increase in insulin resistance and a relative deficiency in insulin secretion.[2] There are other types of diabetes, including the monogenic maturity onset diabetes of the young, which may be associated with pancreatic morphological changes.[3,4] This observation led to interest in defining if pancreatic volume,[5-8] shape, and blood flow would vary in the most common forms of diabetes.

Despite accounting for only 1–2% of pancreatic mass, islets of Langerhans receive around 10–23% of the total pancreatic blood flow.[9,10] In Computed tomography (CT), there is a linear relationship between concentration of iodinated contrast media and the recorded density in Hounsfield units, and it is considered the ideal technique for perfusion images acquisition.[11] Some studies have assessed normal values of pancreatic perfusion by CT.[12,13] Pancreatic perfusion impairments have been evaluated in pancreatic[12,14-18] and hepatic[19] diseases, and modifications of pancreatic perfusion after oncologic therapy have been reported.[20] Satisfactory intra-observer reproducibility of pancreatic perfusion parameters measured by CT, such as time to peak (TTP), blood flow (BF), and blood volume (BV) has already been shown,[21] although experience in performing the readings is essential. Therefore, the aim of this study is to compare quantitatively the pancreatic perfusion by CT in T2DM and non-diabetic subjects.

MATERIAL AND METHODS

We retrospectively investigated seventeen patients with T2DM and 22 non-diabetic subjects who were referred to abdominal CT scan for reasons not related to pancreatic symptoms or disease, from October 2015 to September 2016. The study was performed in accordance non the Helsinki Declaration and was approved by the Ethics Committee of our institution. Exclusion criteria were pregnancy, history of allergic reaction to iodinated contrast media, kidney failure, and history of pancreatic disease.

All patients were scanned in a Siemens Somatom® Force 192-slices scanner. The CT protocol is shown in Table 1. Images were analyzed by a radiologist with 25 years of experience in abdominal imaging blinded to the clinical information, who participated in a training program on abdominal perfusion CT. The following parameters were measured on a workstation Syngo.via® (Siemens) with commercial perfusion CT software (CT Body Perfusion, Siemens) based on the maximum slope model: BF, BV, mean transit time (MTT), and TTP. BF is defined as the volume of flowing blood moving through a given volume of tissue in a specific amount of time. BV is defined as the volume of flowing blood for a given volume of tissue. MTT is defined by the formula – MTT = BV/BF – corresponding to the average amount of time blood takes to transit through a given volume of tissue. TTP is defined as the time elapsed to reach the peak of enhancement in each tissue.

Table 1: CT acquisition protocol.
CT parameters Precontrast Perfusion Venous
Voltage (kVp) 90 80 90
Delay after contrast injection (s) test* 70
Collimation (mm) 192×0.6 48×1.2 128×0.6
Rotation time (s) 0.5 0.25 (full rotation)
1.5 (cycle time)
0.5
Pitch 0.6 0.6 0.8
Slice thickness reconstructed (mm) 3 5 3
Contrast agent dose (mL) 50 70
Contrast injection rate (mL/s) 4 4
Bolus NaCl (mL) 20 20
Depends on test phase, CT: Computed tomography

Reading sections were performed twice by the single reader (session 1 and 2). The reader placed three circular ROI in each part of the pancreas (head, body, and tail) to measure these parameters. The mean value of each parameter on each part of the pancreas was considered for analysis.

Statistical analysis

Data are expressed as mean (±SD), median (interquartile range) or absolute and relative frequencies. Variables were compared by student t test and χ2 between subjects with and without T2DM. Correlations between CT perfusion parameters and clinical and laboratory characteristics were performed by Pearson correlations coefficients. A model of multivariate regression was carried out for CT perfusion parameters and clinical and laboratory characteristics.

RESULTS

A total of 39 patients (M: F ratio = 1.16) were included in the study, with a mean age of 64-year-old and a body mass index of 27.9 kg/m2. Seventeen patients had T2DM, while 22 did not. One patient from each group was excluded due to technical difficulties, which lead to impossibility in measuring pancreatic perfusion parameters (large ascites and improper contrast media injection); the final analysis included 37 patients.

Clinical and laboratory characteristics of patients, according to the DM status, are presented in Table 2. T2DM subjects were older and had higher fasting plasma glucose levels than those without diabetes, as expected. There were more men in T2DM group than in control group. Of note, low-density lipoprotein (LDL)-cholesterol was lower in T2DM group.

Table 2: Clinical and laboratory characteristics of patients.
Diabetes P-value
No (n=21) Yes (n=16)
Age (years) 59±13 70±10 0.004
DM duration (years) 11±5
Men – n(%) 7 (33) 12 (75) 0.012
BMI (kg/m2) 27±5 28±4 0.434
Fasting plasma glucose 105±33 170±60 <0.001
HbA1c 5.7±0.3 7.6±2.4 0.065
C-peptide 1.6±1.4 1.8±0.4 0.902
Cholesterol 196±46 181±55 0.493
HDL 64±21 41±46 0.131
LDL 112±38 73±43 0.028
Triglycerides 96±28 175±147 0.093
DM treatment
Diet 1
Oral medications 12
Insulin 3

DM: Diabetes mellitus, BMI: Body mass index, HDL: High-density lipoprotein, LDL: Low-density lipoprotein

Pancreas volume was similar in patients with and without T2DM (with: 64.3 ± 28.1 vs. without: 63.6 ± 23.1; P = 0.929).

Considering the mean values of BF and TTP in both sessions, no significant differences between these pancreatic perfusion parameters in T2DM patients and controls were found. BV and MTT in pancreatic head, tail, and whole pancreas were lower in patients with T2DM than in controls [Table 3]. No differences between T2DM subjects and controls were observed for BF and TTP. An example of perfusion CT image is shown in Figure 1.

Table 3: Mean values of BF, BV, MTT, and TTP of the reader in both sessions.
Diabetes P-value
No Yes
(n=21) (n=16)
BF head 132.5±33.0 125.7±40.3 0.577
BF body 139.6±37.7 131.6±41.6 0.543
BF tail 144.3±32.9 133.9±38.8 0.385
BF whole pancreas 138.8±32.4 130.4±38.5 0.476
BV head 16.1±2.4 14.0±3.4 0.033
BV body 15.7±3.3 14.3±3.8 0.223
BV tail 16.8±2.5 14.4±3.6 0.023
BV whole pancreas 16.2±2.5 14.2±3.2 0.042
MTT head 7.9±1.2 7.0±1.0 0.018
MTT body 7.4±1.4 7.0±1.4 0.302
MTT tail 7.7±0.9 6.6±1.3 0.005
MTT whole pancreas 7.7±0.9 6.8±1.0 0.016
TTP head 21.2±2.8 22.3±2.0 0.193
TTP body 20.6±2.6 21.6±1.7 0.215
TTP tail 20.5±2.5 21.5±2.0 0.190
TTP whole pancreas 20.8±2.5 21.8±1.8 0.182

TTP: Time to peak, BF: Blood flow, BV: Blood volume, MTT: Mean transit time

Figure 1:
Blood volume color-coded map on computed tomography (CT). Axial CT image showing pancreatic perfusion processed on a workstation (Syngo.via®, Siemens) with commercial perfusion CT sofware (CT Body Perfusion, Siemens) based on the maximum slope model. Red colored areas show more perfused regions of the pancreas (white arrow on the pancreatic tail). Green/blue colored areas indicate less perfused regions (white arrowhead in the pancreatic body).

BV in head, tail, and whole pancreas had an inverse correlation with age (head – r: –0.352, P = 0.032; tail – r: –0.421, P = 0.031; whole pancreas – r: –0.439, P = 0.007) and with fasting plasma glucose (head – r: –0.360, P = 0.031; tail – r: –0.483, P = 0.003; whole pancreas – r: –0.447, P = 0.006). BV in pancreatic head showed also negative correlation with HbA1c (r: –0.607, P = 0.021). MTT in pancreatic head had negative correlation with C-peptide (r: –0.682, P = 0.043), and MTT in tail and in whole pancreas had negative correlation with fasting plasma glucose (tail – r: –0.441, P = 0.007; whole pancreas – r: –0.417, P = 0.011).

In a multivariate linear regression model including T2DM patients and controls, the glycemic status based on HbA1c was independently associated with decrease in BV in whole pancreas (β: –0.884; CI95%: –1.750 to –0.017; P = 0.046).

DISCUSSION

In this sample of subjects undergoing pancreatic perfusion CT, BV and MTT were decreased in those with T2DM in comparison with controls, and no significant differences in pancreatic BF and TTP was observed between these two groups. In addition, we demonstrated that there is a negative correlation between pancreatic BV and MTT and some clinical aspects, such as age, fasting plasma glucose, HbA1c and C-peptide, and higher HbA1c values were independently associated with lower pancreatic perfusion, measured by BV.

Few studies have compared pancreatic perfusion parameters in patients with diabetes and health controls. Miles et al.,[12] in 1995, reported reduced BF in one patient with diabetes; this patient, however, was the only one with diabetes from a total of 12 individuals evaluated. Our study advanced in the evaluation of pancreatic perfusion in patients with T2DM. By comparing a group of T2DM patients with a control group, we demonstrated that BV and MTT are lower in patients with T2DM.

We observed reduced BV in T2DM patients, which may be explained by ischemia in pancreatic microvascular network or by the absence of trophic effect of insulin in pancreatic microcirculatory system. As defined previously, MTT is directly related to BV and inversely to BF. As no differences in BF were detected in this sample, and BV was decreased in the T2DM group, lower MTT was expected in T2DM patients. Pancreatic BV is also reduced in other pancreatic diseases, such as pancreatic adenocarcinoma[14,15] and acute and chronic pancreatitis.[14]

Tal[22] hypothesized that pancreatic microvascular endothelial dysfunction and subsequent islet ischemia is the cause of initial dysfunction and subsequent apoptosis of beta cells seen in T2DM as disease progresses. This mechanism of lesion is like to the observed in other tissues classically associated with damage caused by hyperglycemia, such as the retina, kidney, and peripheral nerves. The same injury is likely to cause vascular endothelial dysfunction and affects blood vessels within the pancreas. In this sense, besides being the main cause of the disease, the pancreas could be also a target-organ for diabetes complications, perpetuating the beta cell damage observed as the disease progress.

The relationship between altered perfusion by CT and microvascular disease has been already demonstrated in other organs, such as the brain[23] and the heart.[23,24] We showed for the first-time differences in pancreatic perfusion CT in patients with T2DM in comparison to non-diabetic patients, probably related to microvascular changes in the pancreas.

Our study had some limitations. First, pancreatic perfusion parameters were obtained by only one reader, which limits reproducibility of our results. Second, this sample was powered to detect differences in BF and some of the negative results may be due to lack of power for other variables.

CONCLUSION

Pancreatic perfusion, assessed by BV and MTT, was significantly lower in T2DM patients in comparison to controls.

Declaration of patient consent

Patient’s consent not required as patients identity is not disclosed or compromised.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

  1. Standards of medical care in diabetes-2016: Summary of revisions. Diabetes Care. 2016;39(Suppl 1):S4-5.
    [CrossRef] [PubMed] [Google Scholar]
  2. Classification and diagnosis of diabetes: Standards of medical care in diabetes-2018. Diabetes Care. 2018;41(Suppl 1):S13-27.
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , , . The role of pancreatic imaging in monogenic diabetes mellitus. Nat Rev Endocrinol. 2012;8:148-59.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , , , , , et al. Carriers of loss-of-function mutations in EXT display impaired pancreatic beta-cell reserve due to smaller pancreas volume. PLoS One. 2014;9:e115662.
    [CrossRef] [PubMed] [Google Scholar]
  5. , , , , , . Pancreatic volume in Type 1 and Type 2 diabetes mellitus. Acta Diabetol. 2001;38:145-9.
    [CrossRef] [PubMed] [Google Scholar]
  6. , , , , , , et al. Pancreas volumes in humans from birth to age one hundred taking into account sex, obesity, and presence of Type-2 diabetes. Clin Anat. 2007;20:933-42.
    [CrossRef] [PubMed] [Google Scholar]
  7. , , , , , , et al. Pancreas volume measurement in patients with Type 2 diabetes using magnetic resonance imaging-based planimetry. Pancreatology. 2014;14:268-74.
    [CrossRef] [PubMed] [Google Scholar]
  8. , , . Islet mass and function in diabetes and transplantation. Diabetes. 1990;39:401-5.
    [CrossRef] [PubMed] [Google Scholar]
  9. . The microvasculature of the pancreas, with emphasis on that of the islets of Langerhans In: , ed. The Pancreas: Biology, Pathobiology, and Disease (2nd ed). New York: Raven Press; . p. :759-68.
    [Google Scholar]
  10. , , , . Blood flow to the rabbit pancreas with special reference to the islets of Langerhans. Gastroenterology. 1980;79:466-73.
    [CrossRef] [Google Scholar]
  11. , , , , , . Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: Acquisition technique, post-processing and initial results. Eur Radiol. 2009;19:2641-6.
    [CrossRef] [PubMed] [Google Scholar]
  12. , , . Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging. Br J Radiol. 1995;68:471-5.
    [CrossRef] [PubMed] [Google Scholar]
  13. , , , , , , et al. Low-dose whole organ CT perfusion of the pancreas: Preliminary study. Abdom Imaging. 2014;39:40-7.
    [CrossRef] [PubMed] [Google Scholar]
  14. , , , , , , et al. Computed tomography perfusion analysis of pancreatic carcinoma. J Comput Assist Tomogr. 2012;36:237-42.
    [CrossRef] [PubMed] [Google Scholar]
  15. , , , , , , et al. Dual-energy perfusion-CT of pancreatic adenocarcinoma. Eur J Radiol. 2013;82:208-14.
    [CrossRef] [PubMed] [Google Scholar]
  16. , , , , , , et al. Perfusion CT can predict tumoral grading of pancreatic adenocarcinoma. Eur J Radiol. 2013;82:227-33.
    [CrossRef] [PubMed] [Google Scholar]
  17. , , , , , , et al. Application of low dose pancreas perfusion CT combined with enhancement scanning in diagnosis of pancreatic neuroendocrine tumors. Pancreatology. 2020;21:240-5.
    [CrossRef] [PubMed] [Google Scholar]
  18. , , , , , , et al. Feasibility of wide detector CT perfusion imaging performed during routine staging and restaging of pancreatic ductal adenocarcinoma. Abdom Radiol (NY). 2021;46:1992-2002.
    [CrossRef] [PubMed] [Google Scholar]
  19. , , , , , , et al. Perfusion measurement of the whole upper abdomen of patients with and without liver diseases: Initial experience with 320-detector row CT. Eur J Radiol. 2012;81:2470-5.
    [CrossRef] [PubMed] [Google Scholar]
  20. , , , , , , et al. Perfusion CT: Noninvasive surrogate marker for stratification of pancreatic cancer response to concurrent chemo-and radiation therapy. Radiology. 2009;250:110-7.
    [CrossRef] [PubMed] [Google Scholar]
  21. , , , , . Intra-and interobserver reproducibility of pancreatic perfusion by computed tomography. Sci Rep. 2019;9:6043.
    [CrossRef] [PubMed] [Google Scholar]
  22. . Type 2 diabetes: Microvascular ischemia of pancreatic islets? Med Hypotheses. 2009;73:357-8.
    [CrossRef] [PubMed] [Google Scholar]
  23. , , , , , , et al. Characterization of microvascular dysfunction after acute myocardial infarction by cardiovascular magnetic resonance first-pass perfusion and late gadolinium enhancement imaging. J Cardiovasc Magn Reson. 2006;8:831-7.
    [CrossRef] [PubMed] [Google Scholar]
  24. , , , , , , et al. Minimally invasive evaluation of coronary microvascular function by electron beam computed tomography. Circulation. 2000;102:2411-6.
    [CrossRef] [PubMed] [Google Scholar]
Show Sections